| THREEPHASE MOTORS : GENERAL FEATURES |
|
CONNECTIONS
The terminal plate is provided with 6 connection terminals, marked
in accordance with 60034-8.
| Frame Size |
63 - 80 |
90 - 100 |
112 |
132 - 160 |
180 |
200 |
225 - 250 |
| Cable Entry |
M20 |
M25 |
M25 |
M32 |
M40 |
M50 |
M40 |
| Number of Entries |
1 |
1 |
2 |
2 |
2 |
2 |
2 |
ENVIRONMENTAL CONDITIONS
Motors are designed to operate at altitutes up to 1000m and ambient
temperature up to 40°C. Rated output will change at the % ratios given
below for different altitutes and ambient tempeartures.
| ALTITUDE |
up to 1000 m |
1500 m |
2000 m |
2500 m |
3000 m |
3500 m |
4000 m |
| Insulation Class |
B |
100 |
97 |
94 |
90 |
86 |
82 |
77 |
| |
F |
100 |
98 |
95 |
91 |
87 |
83 |
78 |
| AMBIENT TEMPERATURE |
30°C |
35°C |
40°C |
45°C |
50°C |
55°C |
60°C |
| Insulation Class |
B |
106 |
103 |
100 |
97 |
92 |
86 |
80 |
| |
F |
105 |
102 |
100 |
97 |
93 |
87 |
82 |
|
METERIALS
| Frame |
|
Housing |
|
Fan |
|
Fan Cover |
|
Endshields |
|
B5 Flange |
|
B14 Flange |
| 63 |
|
Aluminium |
|
Plastic |
|
Steel |
|
Aluminium |
|
Aluminium |
|
Aluminium |
| 71 |
|
|
|
|
|
|
| 80 |
|
|
|
|
|
|
| 90 |
|
|
|
|
|
|
| 100 |
|
|
|
|
|
|
| 112 |
|
|
|
|
|
|
| 132 |
|
|
|
|
|
|
Cast Iron |
| 160 |
|
|
|
Plastic 1) |
|
|
Cast Iron |
|
| 180 |
|
|
|
|
|
|
| 200 |
|
|
|
|
|
|
| 225 |
|
|
|
|
|
|
| 250 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
1) Steel fancover is possible.
|
MOUNTİNG ARRANGEMENTS

|
BEARINGS
Standard motors are equipped with deep groove ball bearings with ZZ
shilds.
250 frame size motors ahave external lubrication.
Bearing & Oil Seal Types
| Frame |
Bearing |
Oil Seal |
| Drive
side |
Nondrive
side |
Drive
side |
Nondrive
side |
| 63 |
6201-2Z |
6201-2Z |
12*22*7 |
12*22*7 |
| 71 |
6202-2Z |
6202-2Z |
15*24*5 |
15*24*5 |
| 80 |
6204-2Z |
6204-2Z |
20*30*7 |
20*30*7 |
| 90 |
6305-2Z |
6205-2Z |
25*40*7 |
25*40*7 |
| 100 |
6306-2Z |
6205-2Z |
30*47*7 |
25*40*7 |
| 112 |
6306-2Z |
6206-2Z |
30*47*7 |
30*47*7 |
| 132 |
6208-2Z |
6208-2Z |
40*62*10 |
40*62*10 |
| 160 |
6309-2Z |
6309-2Z |
45*72*10 |
45*72*10 |
| 180 |
6310-2Z |
6310-2Z |
50*80*10 |
50*80*10 |
| 200 |
6312-2Z |
6312-2Z |
60*90*10 |
60*90*10 |
| 225 |
6313-2Z |
6313-2Z |
65*100*13 |
65*100*13 |
| 250/2 |
6314 |
6313-2Z |
70*112*12 |
65*100*13 |
| 250/4 |
6315 |
6313-2Z |
75*112*12 |
65*100*13 |
|
| |
PAINTING
Our standard range of motors are painted with a gray protective paint
according to RAL 7031(grey). Other colours are also availableupon
customer requests.
FEET
For QS type motors (63-132 frames), feet can be mounted on three
sides, permitting terminal box assembly on the desired side. For
QU types (160-250 frames), feet are detachable and this feature
provides flexibility for different mounting types.
TERMINAL BOX
Motors frame size 63-200 have terminal boxes on top close to the
drive end which can be turned 90°, so that conduits can be at each
side. For the other frame sizes, it is on top and close to the drive
end.
CONDENSATION HOLES
In the basic design, motors are supplied without holes. In case
of customer requests, motors can be supplied with drain holes. Since
these motors are provided with a special plug in the hole, the degree
of protection remains IP 55.
MOTOR IDENTIFICATION SYMBOLS
| |
 |
| QU |
Motor Type |
QU Type |
225 |
. |
Frame Size |
|
Shaft height in millimeters |
| |
|
QS Type |
|
|
|
|
|
| |
|
QH Type |
|
|
|
|
|
| |
|
QB Type |
|
|
|
|
|
| |
|
QM Type |
|
|
|
|
|
| |
|
|
|
|
|
|
| FA |
Contruction Type |
|
M |
. |
Motor Length |
S |
Short |
| |
|
|
|
|
M |
Medium |
| --- |
with feet |
B3,B6,B7,B8,V5,V6/V19 |
|
|
|
L |
Long |
| FA |
with A flange |
B5,V1,V3 |
|
|
|
|
|
| FB |
with B flange |
B14,V18,V19 |
4 |
. |
Number of Poles |
|
2,4,6,8 Poles |
| FC |
with C flange |
B14,V18,V19 |
|
|
|
|
|
| FS |
with special flange |
- |
C |
. |
Core Length |
|
(Does not affect outside dimensions) |
| PA |
with feet and A flange |
B3/B5,V1/V5,V3/V6 |
|
|
|
A |
Short |
| PB |
with feet and B flange |
B3/B14,V5/V18,V6/V19 |
|
|
|
B |
Medium |
| PC |
with feet and C flange |
B3/B14,V5/V18,V6/V19 |
|
|
|
C |
Long |
| PS |
with feet and special flange |
- |
|
|
|
D,CE |
Extra Long |
| X |
without feet;flange and end-shield |
B9,V8,V9 |
|
|
|
|
|
| |
|
43 |
. |
Special Motor Number |
|
01 - ... - 99 |
|
| |
VOLTAGE / 60 Hz
Motors are normally designed for 400V, 50Hz. Other voltages and
60Hz frequency are optional. Our motors wound for 50Hz can be operated
on 60Hz for the same output power. The ratios given below indicate
changes in the given parameters.
| |
60 Hz application
coefficients of 50 H motor |
| 50 Hz Voltage |
60 Hz Application |
Rated Speed |
Rated Power |
Rated Torgue |
Rated Current |
Starting Torque |
Breakdown Torgue |
Starting Current |
| 230 V |
230 V |
1,2 |
1 |
0,83 |
1 |
0,83 |
0,83 |
0,83 |
| 230 V |
265 V |
1,2 |
1,15 |
0,96 |
1 |
0,96 |
0,96 |
0,96 |
| 400 V |
400 V |
1,2 |
1 |
0,83 |
1 |
0,70 |
0,83 |
0,83 |
| 400 V |
460 V |
1,2 |
1,15 |
0,96 |
1 |
0,95 |
0,98 |
0,97 |
|
| |
PERMISSIBLE LOADING ON THE SHAFT END
Frame
size |
Number
of poles |
Horizontal operation

|
Vertical operation
|
| Fr (x=0) (kN) |
Fr (x=max) (kN)
|
Fa1 (kN)
|
Fa2 (kN) |
| 63 |
2 |
0,25 |
0,22 |
0,18 |
0,18 |
| 4 |
0,29 |
0,25 |
0,21 |
0,21 |
| 6 |
0,31 |
0,27 |
0,23 |
0,23 |
| 71 |
2 |
0,30 |
0,26 |
0,21 |
0,21 |
| 4 |
0,35 |
0,29 |
0,25 |
0,25 |
| 6 |
0,37 |
0,31 |
0,27 |
0,27 |
| 8 |
0,38 |
0,32 |
0,28 |
0,28 |
| 80 |
2 |
0,54 |
0,45 |
0,38 |
0,38 |
| 4 |
0,62 |
0,51 |
0,44 |
0,44 |
| 6 |
0,66 |
0,54 |
0,48 |
0,48 |
| 8 |
0,67 |
0,55 |
0,49 |
0,49 |
| 90 |
2 |
0,91 |
0,74 |
0,70 |
0,36 |
| 4 |
0,99 |
0,80 |
0,77 |
0,40 |
| 6 |
1,04 |
0,84 |
0,82 |
0,43 |
| 8 |
1,03 |
0,83 |
0,80 |
0,43 |
| 100 |
2 |
1,21 |
0,96 |
0,91 |
0,36 |
| 4 |
1,31 |
1,04 |
1,01 |
0,40 |
| 6 |
1,38 |
1,09 |
1,07 |
0,43 |
| 8 |
1,38 |
1,09 |
1,07 |
0,43 |
| 112 |
2 |
1,23 |
1,00 |
0,91 |
0,54 |
| 4 |
1,33 |
1,09 |
1,01 |
0,60 |
| 6 |
1,40 |
1,14 |
1,07 |
0,64 |
| 8 |
1,40 |
1,14 |
1,07 |
0,61 |
| 132 |
2 |
1,22 |
0,98 |
0,86 |
0,86 |
| 4 |
1,31 |
1,04 |
0,92 |
0,92 |
| 6 |
1,34 |
1,08 |
0,95 |
0,95 |
| 8 |
1,42 |
1,14 |
1,03 |
1,03 |
| 160 |
2 |
2,22 |
1,72 |
1,59 |
1,59 |
| 4 |
2,34 |
1,82 |
1,71 |
1,71 |
| 6 |
2,34 |
1,82 |
1,71 |
1,71 |
| 8 |
2,48 |
1,92 |
1,83 |
1,83 |
| 180 |
2 |
2,68 |
2,12 |
1,94 |
1,94 |
| 4 |
2,82 |
2,23 |
2,07 |
2,07 |
| 6 |
2,93 |
2,31 |
2,17 |
2,17 |
| 8 |
2,92 |
2,31 |
2,16 |
2,16 |
| 200 |
2 |
3,80 |
3,04 |
2,79 |
2,79 |
| 4 |
3,95 |
3,16 |
2,93 |
2,93 |
| 6 |
4,07 |
3,26 |
3,05 |
3,05 |
| 8 |
3,95 |
3,16 |
2,93 |
2,93 |
| 225 |
2 |
4,45 |
3,65 |
3,25 |
3,25 |
| 4 |
4,59 |
3,60 |
3,39 |
3,39 |
| 6 |
4,73 |
3,71 |
3,52 |
3,52 |
| 8 |
4,53 |
3,55 |
3,32 |
3,32 |
| 250 |
2 |
4,97 |
3,93 |
3,61 |
2,94 |
| 4 |
5,78 |
4,57 |
4,26 |
3,15 |
Calculations are based on 20,000h (L10aah) bearing life time and
the actual values will differ if
radial and axial loads act at the same time. Mechanical strength
of the endshields should
also be considered for critical applications.
Value of force Fr acting on any point of the shaft end (between
points X=max and X=0) may
be calculated according to the following formula:
Where;
Fx0 - value of Fr force acting on the beginning of the shaft end
Fxmax - value of Fr force acting on the shaft end
E - length of the shaft end
|
|